Select your language

Auswahl
Auswahl

TMG IO-Link Master Test Device

TMG IO-Link Test Device The TMG IO-Link Master Test Device is intended for the system test of IO-Link masters. It does not replace the master test system for the IO-Link conformance test. This only tests the correctness of the protocol processing on one port. For the system test, however, the IO-Link master should be tested on all its ports simultaneously, each with different data lengths and different time behavior. Ideally, test devices should be connected to all ports in order to test the master with the highest load.

Especially for the extreme values of IO-Link configurations there are no, only a few or sometimes expensive IO-Link devices. Therefore TMG TE has developed the IO-Link Master Test Device. This provides a wide range of different IO-Link configurations, which simplify the system test and allow a good test depth. We always recommend to first perform the protocol test with the specified test system and after passing the test to perform the system test with TMG IO-Link Master Test Devices on all ports.

The TMG IO-Link Master Test Device supports the IO-Link Firmware Update Profile, so that we will be able to offer even more configurations and also more test functions in the future.

  • Is intended for the system test of IO-Link masters
  • Simple connection of the IO-Link master via an M12 connector
  • Support of the IO-Link Device Firmware Update Profile
  • Various test suites are available that can be imported to the TMG IO-Link master test device via the firmware update profile:
    • Test Suite according to IO-Link specification V1.1.2
      • More than 30 test configurations are available for the system test of an IO-Link master
    • Test Suite according IO-Link Spezifikation V1.1.3
    • Test Suite for EMC tests
      • is used to test the IO-Link-specific electromagnetic compatibility (EMC)
  • Diagnostic
    • In addition to the normal IO-Link operation, some detectable protocol errors are detected and the statistics are displayed.
      • Number of ISDU Aborts, Number of Disconnects, Number of Parity Errors
  • Profile
    • Common Profile
    • IO-Link Device Firmware Update Profile

Test Suite V1.1.2

Test configurations

Test Suite V1.1.2 is described here as an example. Test Suite V1.1.3 has a similar structure.
There are 34 test configurations to choose between.
The following properties of the devices are offered:

IO-Link V1.1 compatible with V1.0
V1.1 not compatible with V1.0
V1.0
ISDU with and without
Bitrate COM1, COM2, COM3
MinCycleTime 400 µs to 132,8 ms
Input process data 0 to 15 Bits, 2 to 32 Bytes
Output process data 0 to 15 Bits, 2 to 32 Bytes
Simulation process data cyclic and static
Pre Operate–On-Request-Data IOL V1.1: 1,4,8,32 / IOL V1.0: n.a
Operate - On-Request Data IOL V1.1: 1,4,8,32 / IOL V1.0: 1
Events activable
SIO Mode with and without
Parameter
DirectParameters_2 DirectParameterOverlay
ISDU Commands
Simple Data Types
RecordT
ArrayT

Diagnose

In addition to normal IO-Link operation, some detectable protocol errors are detected and counted.

  • Number of ISDU Aborts
  • Number of Disconnects
  • Number of Parity Errors

Set test configurations

The TMG IO-Link Master Test Device realizes the different test configurations by device compatibility. So no new firmware has to be loaded to set up a new test configuration, but this is done by presetting an assigned device ID.

This can be accomplished in two ways:

  • Due to Device Compatibility
    The port configuration of the IO-Link master is set to "compatible" or to a backup mode. The vendor ID (TMG, 335, 0x014F) and the device ID for the respective test setting are configured with the respective IODD. When establishing the connection, the IO-Link master will then change the IO-Link master test device to the device ID of the test configuration.
  • By parameterization
    If you do not want to make the setting by the port configuration of the IO-Link master, you can also do this by setting a parameter e.g. by the TMG USB IO-Link Master V2 or by the master to be tested itself.

Test Suite: EMV Test

The "TMG IO-Link EMC Test Device" is an additional firmware that can be loaded to the TMG IO-Link Master Test Device via firmware update (included in delivery). The device is used to support IO-Link specific electromagnetic compatibility (EMC) tests. It generates a different random 8-bit process datum in each IO-Link cycle. It checks the process output data received from the IO-Link master and compares it with the previously sent process input data (for more information, see Appendix H of the IO-Link Interface and System Specification V1.1.3). If the output data deviates from the input data, an error counter is incremented. If the IO-Link master sends the same frame twice, a retry counter is incremented. If the TMG IO-Link EMC test device loses the connection to the IO-Link master, a connection loss counter is incremented.

The test suite "TMG IO-Link EMC Test Device" has the following configurations:

Prozess-Eingangsdaten 8 Bits
Output process data 8 Bits
Pre Operate–On-Request-Data 8 Bits
Operate - On-Request Data 1 Bits
ISDU with
Bitrate COM 1, COM 2, COM 3
MinCycleTime 18.0ms, 2.3ms, 0.4ms
IO-Link V1.1
Compatibility with IO-Link V1.0 without
SIO Mode without

  • TMG IO-Link Master Test Device
  • Test Suites
  • Manual (PDF)
  • IODD’s